Based on the combustion and heat transfer characteristics of oil and gas boilers, Devotion has developed a new type of angle-tube boiler products together with Shanghai Industrial Boiler Research Institute, combined with the mature angle-tube boiler technology. Devotion angle tube boiler series has advanced design, high boiler operation efficiency, high combustion efficiency and beautiful appearance, and getting high attention from clients after being introduced to the market.
Model | QXS29 | QXS46 | QXS58 | QXS70 | QXS91 | QXS116 | QXS140 | SZS210 | |
Rated Power | MW | 29 | 46 | 58 | 70 | 91 | 116 | 140 | 210 |
Rated Pressure | MPa | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 |
Outlet Water Temperature | ℃ | 130 | 130 | 130 | 130 | 130 | 130 | 130 | 130 |
Inlet Water Temperature | ℃ | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 |
Circulating Water Volume | m³/h | 414 | 657 | 829 | 1000 | 1300 | 1657 | 2000 | 3000 |
Hydraulic Boiler Test | MPa | 2.00 | 2.00 | 2.00 | 2.00 | 2.00 | 2.00 | 2.00 | 2.00 |
Exhaust Temperature | ℃ | <90 | <90 | <90 | <90 | <90 | <90 | <90 | <90 |
Boiler Fuel | \ | Natural Gas:8500kcal/Nm³(35.53Mj/Nm³) | |||||||
N.gas Consumption | Nm3/h | 3074 | 4876 | 6148 | 7420 | 9646 | 12296 | 14840 | 22260 |
Boiler Efficiency | % | ≥95 | ≥95 | ≥95 | ≥95 | ≥95 | ≥95 | ≥95 | ≥95 |
Smoke Resistance | Pa | 1200 | 1200 | 1500 | 1500 | 1600 | 1800 | 2000 | 2000 |
Installation Dimensions | m | 10.05 x5.42 x12.00 |
10.70 x6.00 x13.00 |
11.60 x6.40 x13.50 |
11.60 x9.50 x13.5 |
12.50 x9.60 x13.50 |
12.8 x9.80 x15.60 |
13.8 x10.80 x16.60 |
15.8 x12.80 x16.80 |